35 / 66 page ![]() 2018-2021 Microchip Technology Inc. DS20005769C-page 35 24CS512 11.0 MANUFACTURER IDENTIFICATION REGISTER The 24CS512 offers the ability to query the device for the manufacturer, density and revision information. By using the reserved 7-bit host code F8h, the device will return a 24-bit value that corresponds with the reserved I2C identifier value, along with further data to signify a 512-Kbit density and the device revision. To read the Manufacturer ID data, the host must send a Start condition, followed by a reserved host code F8h, specified to which all devices on the bus that support the Manufacturer ID will ACK. Next, the device address byte is sent, followed by a new Start condition. The device address byte consist of the EEPROM device type identifier (‘1010‘), the selected hardware client address and the don’t care value for the R/W bit. Then, the reserved host code F9h is sent and only the specific device that was previously identified will return an ACK. Now the 24CS512 is ready to return its unique 24-bit Manufacturing ID value. The first byte of Manufacturer ID data contains the eight Most Significant bits (D23-D16) of the 24-bit data value. The host can then return an ACK to indicate it success- fully received the data, upon which the device will send the second byte (D15-D8) of Manufacturer ID data. The process repeats until all three bytes have been read out and the host sends a NACK (logic ‘1’) to complete the sequence. If the host ACKs (logic ‘0’) the third byte, the internal Address Pointer will roll over back to the first byte of Manufacturer ID data. FIGURE 11-1: MANUFACTURER IDENTIFICATION REGISTER READ SEQUENCE Note: A Repeated Start condition must be sent to the 24CS512 when reading the Manu- facturer ID. Once a Stop condition is sent, the internal Address Pointer will reset and the Manufacturer ID will not be read. SCL MSb MSb MSb SDA 123 45 6 7 8 9 12 3 4 5 6 7 8 9 1 2 3 45 6 7 8 9 Host Code F9h Device Address Byte Host Code F8h 11 1 1 0 01 0 1 0 A2 A1 A0 x0 1 1 1 1 1 0 0 01 10 0 ACK from Client ACK from Client ACK from Client Start by Host MSb MSb MSb 12 3 4 5 6 7 8 9 123 45 6 7 8 9 1 2 3 4 5 6 7 8 9 Manufacturer ID – Byte 2 Manufacturer ID – Byte 1 Manufacturer ID – Byte 0 D23 D22 D21 D20 0 D16 D15 D14 D13 D12 D11 D10 D9 D8 01 D19 D18 D17 NACK from Host ACK from Host ACK from Host Stop by Host D7 D6 D5 D4 D3 D2 D1 D0 Repeated Start by Host |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |