44 / 112 page ![]() 44 Am186TMER and Am188TMER Microcontrollers Data Sheet DRAF T Pseudo Static RAM (PSRAM) Support The Am186ER and Am188ER microcontrollers support the use of PSRAM devices in low memory chip-select (LCS) space only. When PSRAM mode is enabled, the timing for the LCS signal is modified by the chip-select control unit to provide a CS precharge period during PS R A M a cce sse s. T h e 5 0 - M H z t i ming o f t h e Am186ER and Am188ER microcontrollers is appropri- ate to allow 70-ns PSRAM to run with one wait state. PSRAM mode is enabled through a bit in the Low Mem- ory Chip-Select (LMCS) Register. The PSRAM feature is disabled on CPU reset. In addition to the LCS timing changes for PSRAM pre- charge, the PSRAM devices also require periodic re- fresh of all internal row addresses to retain their data. Although refresh of PSRAM can be accomplished sev- eral ways, the Am186ER and Am188ER microcontrol- lers implement auto refresh only. The Am186ER and Am188ER microcontrollers gener- ate RFSH, a refresh signal, to the PSRAM devices when PSRAM mode is enabled. No refresh address is required by the PSRAM when using the auto refresh mechanism. The RFSH signal is multiplexed with the MCS3 signal pin. When PSRAM mode is enabled, MCS3 is not available for use as a chip-select signal. The refresh control unit must be programmed before accessing PSRAM in LCS space. The refresh counter in the Clock Prescaler (CDRAM) Register must be con- figured with the required refresh interval value. The re- fresh counter reload value in the CDRAM Register should not be set to less than 18 (12h) in order to pro- vide time for processor cycles between refreshes. The refresh address counter must be set to 000000h to pre- vent the MCS3–MCS0 or PCS6–PCS0 chip selects from asserting. UCS may randomly assert during a PSRAM refresh. LCS is held High and the A bus is not used during re- fresh cycles. The LMCS Register must be configured to external ready ignored (R2 = 1) with one wait state (R1–R0 = 01b), and the PSRAM mode enable bit (SE) must be set. The ending address of LCS space in the LMCS Register must also be programmed. PERIPHERAL CONTROL BLOCK (PCB) The integrated peripherals of the Am186ER and Am188ER microcontrollers are controlled by 16-bit read/write registers. The peripheral registers are con- tained within an internal 256-byte control block. The registers are physically located in the peripheral de- vices they control, but they are addressed as a single 256-byte block. Figure 9 on page 46 shows a map of these registers. Reading and Writing the PCB Code intended to execute on the Am188ER microcon- troller should perform all writes to the PCB registers as byte writes. These writes will transfer 16 bits of data to the PCB Register even if an 8-bit register is named in the instruction. For example, out dx, al results in the ax value being written to the port address in dx. Reads to the PCB should be done as word reads. Code written in this manner will run correctly on the Am188ER and Am186ER microcontrollers. Unaligned reads and writes to the PCB result in unpre- dictable behavior on both the Am186ER and Am188ER microcontrollers. For a complete description of all the registers in the PCB, refer to the Am186ER and Am188ER Microcon- trollers User’s Manual, order #21684. CLOCK AND POWER MANAGEMENT The clock a nd powe r ma na ge me nt un it of th e Am186ER and Am188ER microcontrollers includes a phase-locked loop (PLL) and a second programmable system clock output (CLKOUTB). Phase-Locked Loop (PLL) In a traditional 80C186/80C188 design, the internal clock frequency is half the frequency of the crystal. Because of the internal PLL on the Am186ER and Am188ER micro- controllers, the internal clock generated by both micro- controllers can operate at up to four times the frequency of the crystal. The Am186ER and Am188ER microcon- trollers operate in the following modes: n Divide by Two—Frequency of the system clock is half the frequency of the crystal with PLL disabled. n Times One—Frequency of the system clock will be the same as the external crystal with PLL enabled. n Times Four—Frequency of the system clock is four times the frequency of the crystal with PLL enabled. The default Times Four mode must be used for processor frequencies above 40 MHz. The Divide by Two mode should be used for frequencies below 16 MHz. The clock- ing mode is selected using CLKSEL1 and CLKSEL2 on reset. Table 8 provides the maximum and minimum fre- quencies for X1, X2, and CLKOUTA according to clocking mode. Table 8. Maximum and Minimum Clock Frequencies Mode X1/X2 Max X1/X2 Min CLKOUTA Max CLKOUTA Min Divide by 2 40 MHz 30 MHz 20 MHz 15 MHz Times 1 40 MHz 16 MHz 40 MHz 16 MHz Times 4 12.5 MHz 4 MHz 50 MHz 16 MHz |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |