Numer części AN2971
Szczegółowy opis  Using the typical temperature characteristics of 32 KHz crystal
PDF  12 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Producent  STMICROELECTRONICS [STMicroelectronics]
Strona internetowa  http://www.st.com
Logo STMICROELECTRONICS - STMicroelectronics

AN2971 Arkusz danych(HTML) 6 Page - STMicroelectronics

Back Button AN2971 Datasheet HTML 2Page - STMicroelectronics AN2971 Datasheet HTML 3Page - STMicroelectronics AN2971 Datasheet HTML 4Page - STMicroelectronics AN2971 Datasheet HTML 5Page - STMicroelectronics AN2971 Datasheet HTML 6Page - STMicroelectronics AN2971 Datasheet HTML 7Page - STMicroelectronics AN2971 Datasheet HTML 8Page - STMicroelectronics AN2971 Datasheet HTML 9Page - STMicroelectronics AN2971 Datasheet HTML 10Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 12 page
background image
Example
AN2971
6/12
Doc ID 15627 Rev 1
3
Example
The first step is to determine the temperature. That in turn is used to look up the expected
amount of drift, as shown in step 2. The easiest way to do this is to use a table as illustrated
in Figure 6, which shows an expected drift of –43 ppm at 58°C. Thus, the oscillator should
be adjusted for a 43 ppm shift in the opposite direction.
In step 3, the factory calibration value is used as a starting point on the capacitance-ppm
curve in Figure 7. The factory calibration value of 0x14 corresponds to a capacitance of
+5 pF (above the nominal 12.5 pF). That corresponds to –7.78 ppm as shown in Figure 8.
Adding 43 ppm to that gives +35.22 ppm. Thus, capacitance must be removed to speed up
the oscillator.
In step 4, the user finds the ppm value nearest 35.22 in the list in Figure 8. In this case, that
is 34.97 ppm, which calls for an analog calibration value of 0xA9 (which corresponds to
–10.25 pF). This value is then placed into the user analog calibration register at address
0x12, and the OTP bit is cleared (address 0x13) forcing the device to employ the user
analog calibration value in lieu of the factory calibration value.
This results in the oscillator running at a slightly different speed which in turn helps it keep
time more accurately at the ambient temperature.
By performing this procedure periodically, the application can keep the timekeeping
accuracy at an acceptable level.
Using these few simple steps, users can greatly improve the timekeeping performance of
their M41T83 and M41T93 real-time clock devices.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Arkusz danych Pobierz

Go To PDF Page


Link URL



Czy Alldatasheet okazała się pomocna?  [ DONATE ] 

O Alldatasheet   |   Reklama   |   Kontakt   |   Polityka prywatności   |   Link do karty katalogowej    |   Linki   |   Lista producentów
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com