8 / 33 page ![]() Test board: design and evaluation AN4007 8/33 Doc ID 022455 Rev 2 Figure 4. Line and load regulation 1.2 Efficiency and light load measurements Any external power supply (EPS) must be capable to meet the international regulation agency limits. The european code of conduct (EC CoC) and US department of energy (DoE- US EISA 2007) limits are taken as reference. EPS limits are fixed up to 76.4%, when the average efficiency is measured. The average efficiency measures the average value at 25%, 50%, 75% and 100% of the rated output power, at both 115 Vac and 230 Vac. Table 4 and Table 5 show the results: 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.95 5.00 5.05 5.10 5.15 115Vac 230Vac Output current [mA] AM11343v1 Table 4. Efficiency at 115 VAC Load IOUT VOUT POUT PIN Efficiency 25% 0.754.973.734.76 78.31% 50% 1.5 4.97 7.46 9.65 77.25% 75% 2.25 4.97 11.17 14.75 75.74% 100% 3 4.97 14.91 19.86 75.08% Average efficiency 76.59% |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|