| Zakładka z wyszukiwarką danych komponentów |
|
AN3307 Arkusz danych(PDF) 28 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3307 Arkusz danych(HTML) 28 Page - STMicroelectronics |
|
28 / 37 page ![]() Class B solution structure AN3307 28/37 Doc ID 18186 Rev 4 interval (more than +/- 25% of its nominal value), the CPU clock source is immediately switched back to HSI, and HSE fail status is returned. Otherwise the test returns the OK status. In either case, the CPU clock is switched back to the default HSI source after the test is finished. Figure 13. Clock frequency measurement principle MS18599V1 Accepted range SysTick Timer (on HSI / HSE) RTC Timer (always on LSE) F ~ Ref F << Ref F >> Ref Run time measurement Initial reference measurement Reference level Zero level Auto reload level Zero level |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|