DP8105 Arkusz danych(PDF) 21 Page - Power-One |
|
|
|||||||||||||||||||||||||||||
DP8105 Arkusz danych(HTML) 21 Page - Power-One |
|
21 / 35 page ![]() DP8105 5A DC-DC Intelligent dPOL Data Sheet 8V to 14V Input •••• 0.7V to 5.5V Output BCD.00261 Rev. 1.0, 12 Feb 2013 www.power-one.com Page 21 of 35 1.1.1.2 Grouping of dPOLs dPWER ® dPOLs can be arranged in groups of up to 4, 8, 16 or 32 dPOLs (depending upon the DPM model used). Membership in a group is set in the GUI in the DPM / Configure / Devices dialog, and implemented in hardware by connecting the OK pins of each dPOL in the group to the matching OK input on the DPM. In order for a particular Fault or Error to propagate through the OK line, Propagation needs to be checked in the GUI dPOL Configure / Fault Management Window Figure 34. Figure 34. DPM Configure Faults Window Note that the turn-off type of the fault as it propagates through the DPM will remain unchanged. Propagation options for dPOLs can be read or set in the dPOL PC3 register shown in Figure 35. Figure 35. Protection Configuration Register PC3 7.4.7.1 Front End and Crowbar If an error is propagated to at least the Group level, the DPM can also be configured to generate commands to turn off a front end (a DC-DC converter generating the intermediate bus voltage) and to trigger an optional crowbar protection to accelerate removal of the IBV voltage. 7.4.7.2 Propagation Process Understanding Fault and Error propagation is easier with the following examples. The First example is of of non-propagation from a dPOL, as shown in Figure 36. An undervoltage error shuts down the Vo, but since propagation was not enabled, OK-A is not pulled down and Vo2 stays up. PC3: Protection Configuration Register 3 Address: 0x02 U U R/W-1 R/W-1 R/W-1 R/W-1 R/W-1 R/W-1 --- --- TRP OTP OCP UVP OVP PVP Bit 7 Bit 0 Bit 7:6 Unimplemented: Read as ‘0’ Bit 5 TRP: Tracking Protection Propagation 0 = disabled 1 = enabled Bit 4 OTP: Over Temperature Protection Propagation 0 = disabled 1 = enabled Bit 3 OCP: Over Current Protection Propagation 0 = disabled 1 = enabled Bit 2 UVP: Under Voltage Protection Propagation 0 = disabled 1 = enabled Bit 1 OVP: Over Voltage Protection Propagation 0 = disabled 1 = enabled Bit 0 PVP: Reserved |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |