Zakładka z wyszukiwarką danych komponentów
  Polish  ▼
ALLDATASHEET.PL

X  

DP8105 Arkusz danych(PDF) 4 Page - Power-One

Numer części DP8105
Szczegółowy opis  8V to 14V Input , 0.7V to 5.5V Output
PDF  35 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Producent  POWER-ONE [Power-One]
Strona internetowa  http://www.power-one.com
Logo POWER-ONE - Power-One

DP8105 Arkusz danych(HTML) 4 Page - Power-One

  DP8105 Datasheet HTML 1Page - Power-One DP8105 Datasheet HTML 2Page - Power-One DP8105 Datasheet HTML 3Page - Power-One DP8105 Datasheet HTML 4Page - Power-One DP8105 Datasheet HTML 5Page - Power-One DP8105 Datasheet HTML 6Page - Power-One DP8105 Datasheet HTML 7Page - Power-One DP8105 Datasheet HTML 8Page - Power-One DP8105 Datasheet HTML 9Page - Power-One Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 35 page
background image
DP8105 5A DC-DC Intelligent dPOL Data Sheet
8V to 14V Input •••• 0.7V to 5.5V Output
BCD.00261 Rev. 1.0, 12 Feb 2013
www.power-one.com
Page 4 of 35
4.3
Protection Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
Output Overcurrent Protection
Type
Default
Programmable
Non-Latching, 130ms period
Latching/Non-Latching
Threshold
Default
Programmable in 11 steps
36
132
132
%IOUT
%IOUT
Threshold Accuracy
-20
+20
%IOCP.SET
Output Overvoltage Protection
Type
Default
Programmable
Non-Latching, 130ms period
Latching/Non-Latching
Threshold
Default
Programmable in 10% steps
110
130
130
%VO.SET
%VO.SET
Threshold Accuracy
Measured at VO.SET=2.5V
-2
2
%VOVP.SET
Delay
From instant when threshold is exceeded until
the turn-off command is generated
6
µ
s
Turn Off Behavior
3
Default
Programmable to
Emergency Off
Critical Off / Emergency Off
Output Undervoltage Protection
Type
Default
Programmable
Non-Latching, 130ms period
Latching/Non-Latching
Threshold
Default
Programmable in 5% steps
75
75
90
%VO.SET
%VO.SET
Threshold Accuracy
Measured at VO.SET=2.5V
-2
2
%VUVP.SET
Delay
From instant when threshold is exceeded until
the turn-off command is generated
6
µ
s
Turn Off Behavior
3
Default
Programmable to
Sequenced Off
Sequenced / Critical Off
Overtemperature Protection
Type
Default
Programmable
Non-Latching, 130ms period
Latching/Non-Latching
Turn Off Threshold
Temperature is increasing
120
°
C
Turn On Threshold
Temperature is decreasing after the module was
shut down by OTP
4
110
°
C
Threshold Accuracy
-5
5
°
C
Delay
From instant when threshold is exceeded until
the turn-off command is generated
6
µ
s
Turn Off Behavior
3
Default
Programmable to
Sequenced Off
Sequenced / Critical Off
Tracking Protection (when Enabled)
3 Sequenced Off: The turn-off follows the turn-off delay and slew-rate settings; Critical Off: At turn-off both low and high switches are
immediately disabled; Catastrophic Off: At turn-off the high side switch is disabled and the low side switch is enabled.
4
OTP clears when Overtemp Warning (Status Register TW bit) turns off.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


Arkusz danych Pobierz

Go To PDF Page


Link URL



Czy Alldatasheet okazała się pomocna?  [ DONATE ] 

O Alldatasheet   |   Reklama   |   Kontakt   |   Polityka prywatności   |   Link do karty katalogowej    |   Linki   |   Lista producentów
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com