| Zakładka z wyszukiwarką danych komponentów |
|
DP8105 Arkusz danych(PDF) 19 Page - Power-One |
|
|
|||||||||||||||||||||||||||||
DP8105 Arkusz danych(HTML) 19 Page - Power-One |
|
19 / 35 page ![]() DP8105 5A DC-DC Intelligent dPOL Data Sheet 8V to 14V Input •••• 0.7V to 5.5V Output BCD.00261 Rev. 1.0, 12 Feb 2013 www.power-one.com Page 19 of 35 7.4.3 Errors This protection group includes only overvoltage protection. 7.4.3.1 Overvoltage Protection The overvoltage protection is active whenever the output voltage of the dPOL exceeds the pre-bias voltage (if any). If the output voltage exceeds the overvoltage protection threshold, the overvoltage error signal is generated, the dPOL turns off, and the OV bit in the register ST is changed to 0. The high side switch is turned off instantly, and simultaneously the low side switch is turned on to ensure reliable protection of sensitive loads. The low side switch provides low impedance path to quickly dissipate energy stored in the output filter and achieve effective voltage limitation. The OV threshold can be programmed from 110% to 130% of the output voltage setpoint, but not lower than 0.5V. Also the OV threshold will always be at least 0.25V above the setpoint. 7.4.4 Fault and Error Latching The user has the option of setting up any protection option as either latching/non-latching and propagating or non-propagating. Propagation and Latching for each dPOL is set in the GUI (Figure 31 below) or directly via the I 2C by writing into the PC1 register shown in Figure 32. Figure 31. GUI dPOL Fault Latching and Propagation Option Window If the non-latching protection is selected, a dPOL will attempt to restart every 130ms until the condition that triggered the protection is removed. When restarting, the output voltages follow tracking and sequencing settings. If the latching type is selected, a dPOL will turn off and stay off. The dPOL can be turned on after 130ms, if the condition that caused the fault is removed and the respective bit in the ST register was cleared, or the Turn On command was recycled, or the input voltage was recycled. PC1: Protection Configuration Register 1 Address: 0x00 R/W-0 R/W-1 R/W-0 R/W-0 R/W-0 R/W-0 R/W-1 R/W-1 TRE PVE TRC OTC OCC UVC OVC PVC Bit 7 Bit 0 Bit 7 TRE: Tracking fault enable 1 = enabled 0 = disabled Bit 6 PVE: Phase voltage error enable 1 = enabled 0 = disabled Bit 5 TRC: Tracking Fault Protection Configuration 1 = latching 0 = non-latching Bit 4 OTC: Over Temperature Protection Configuration 1 = latching 0 = non-latching Bit 3 OCC: Over Current Protection Configuration 1 = latching 0 = non- latching Bit 2 UVC: Under Voltage Protection Configuration 1 = latching 0 = non- latching Bit 1 OVC: Over Voltage Protection Configuration 1 = latching 0 = non- latching Bit 0 PVC: Phase Voltage Protection Configuration 1 = latching 0 = non- latching |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |