| Zakładka z wyszukiwarką danych komponentów |
|
QG80331M800 Arkusz danych(PDF) 20 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
QG80331M800 Arkusz danych(HTML) 20 Page - Intel Corporation |
|
20 / 67 page ![]() 20 Specification Update Intel® 80331 I/O Processor Non-Core Errata 5. Boundary Scan data gets inverted Problem: Data driven in during boundary scan gets inverted during the capture phase. During parallel loading on a pin, an external zero on data in gets inverted to one for data out. This is a violation of the IEEE 1149.1 Specification. Implication: Boundary scan cannot be used with A-1 stepping. Workaround: No workaround. Do not use boundary scan. Status: Fixed. Fixed in B-0 stepping. See the Table , “Summary Table of Changes” on page 9. 6. BIU interrupt does not occur on Internal Bus Write Master Abort Issue: Software developers be aware that an interrupt is not generated when the Bus Interface Unit gets master aborted on an internal bus write. Implication: When left undetected, it could cause data corruption. Workaround: The status bit needs to be polled by software. Status: Fixed. Fixed in B-0 stepping. See the Table , “Summary Table of Changes” on page 9 7. CRC value calculated by DMA unit is not compliant with iSCSI Problem: Several issues with the CRC generation engine have caused it to not be compliant with iSCSI in A-1 step. Implication: CRC cannot be used with A-1 stepping. Workaround: No workaround. Status: Fixed. Fixed in B-0 stepping. See the Table , “Summary Table of Changes” on page 9. 8. ATU Outbound Direct Window overlaps with PBI exception vectors Problem: When the PBI exception vectors are enabled (PBCR.3), it claims addresses 00h-3fh. When the ATU outbound direct window is enabled, it claims addresses 28h-7fffffffh. There is an overlap between 28h-3fh, where both devices claim the internal bus transaction. For writes, this may not be an issue, since the only transaction here is a posted write to the ATU. For reads, the PBI handles the transaction as a single data phase disconnect, and the ATU internally handles it as a split transaction. Implication: The agent which issued the internal bus transaction does not claim the returning data, since the transaction has been completed by the PBI. This causes the data from PCI to not be returned to the issuing internal bus agent. Workaround: Consider address range of 28h-3Fh reserved. Status: Fixed. Fixed in B-0 stepping. See the Table , “Summary Table of Changes” on page 9. 9. S_REQ64# Initialization Pattern Timing Violation in PCI-33 Mode Problem: The PCI Local Bus Specification, Revision 2.3 states RST# to REQ64# Hold time is 0 ns minimum and 50 ns maximum. The 80331 drives the REQ64# signal for three cycles after RST# deasserts. Therefore, in PCI-33 mode, this is 90 ns, which violates the 50 ns maximum. All other PCI and PCI-X modes are within the specification (i.e., PCI-66 is 45 ns). Implication: Some PCI targets may not interpret the REQ64# signal correctly, causing it to operate in 32-bit mode. Workaround: When running in PCI-33 mode, make sure PCI target can handle the extra 40 ns. Status: No Fix. Not to be fixed. See the Table , “Summary Table of Changes” on page 9. |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |