29 / 144 page ![]() STV3550 29/144 ● The Inflexion point is dependant either on the average brightness (when using brightness estimator values) or the input value (when using manual mode). ● The Range parameter modifies the slope of the Ym segment. Slope values are algorithm- dependant. The Gain parameter modifies the overall curve gain in relation to the transfer curve (Yout = Yin). Figure 15: Yce = Ylp + Yg Figure 16: Original Curve Figure 17: Example Curve after applying a Gain Factor of 2 Ym 0255 255 OUT IN Yhl Yll 0 255 Gain 0 255 |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|